B12 VI-B

B12 VI-B Ultrasonic Heat Meter is an innovative heat meter with static flow sensor based on the ultrasonic measuring principle. B12 VI-B is designed for measuring the use of heating in which water is the heat/cool bearing medium.

It utilizes ultrasonic measuring methodology and microprocessor technology. All calculation and flow measuring circuits are designed on one single board, thus offering exceptional accuracy and reliability. B12 VI-B gives importance to flexibility with its programmable functions and install-uninstall communication units.

With its size options from DN15 to DN40, it enables flow rate metering from 0.03 m3/h to 20 m3/h.

Category:

Description

IoT Ready

B12 VI-B supports multiple communication interfaces for both wired and wireless which suitable for any type of installation environment, e.g. M-Bus, RS485 (Modbus), Pulse, LoRaWAN (433MHz, 868MHz, 915MHz, 923MHz), Sigfox.

Flexible Battery Life Span

B12 VI-B has no moving parts, presents as IP65, and its body is fabricated from durable brass material. This robust design makes the B12 VI-B maintenance-free and highly precise throughout its flexible 6 or 10 or 15 years battery life depends upon customers’ needs.

Ultrasonic Flow Metering Unit

Ultrasonic flow meter measures by the transfer of ultrasound signals between transducers with the help of mirrors.

Temperature Metering Unit

PT1000 type heat sensors are used which they are calibrated, certified. If input water temperature metering prob is integrated with the meter body where flow meter is, thus the output water temperature metering prob is mounted to a suitable point on the network return water direction. Also meter could be installed in out flow position. Default cable length is 1.5m, but 3m length is also available as per request.

Calculator Unit

It is the unit that process energy calculation by the flow rate data received from flow rate metering unit and temperature data received from temperature metering unit. Its calibration is performed in software at factory.Calculated energy and other information is displayed on the LCD when button is pushed. These information may be remotely read via optical port and communication unit.

 

Specifications

Model

B12 VI-B-15

B12 VI-B-20

B12 VI-B-25

B12 VI-B-32

B12 VI-B-40

Pipe Diameter

DN15

DN20

DN25

DN32

DN40

Minimum Flow Rate, qi (m³/h)

0.03

0.05

0.07

0.12

0.2

Permanent Flow Rate, qp (m³/h)

1.5

2.5

3.5

6

10

Maximum Flow Rate, qs (m³/h)

3.0

5.0

7.0

12

20

Connection

G3/4′

G1′

G1 1/4′

G1 1/2′

G2′

Length (mm)

110

130

160

180

200

Width (mm)

96

105

114

120

130

Temperature

Range: 4℃ – 95℃, T: 3k – 65k

Temperature Sensor

A pair of PT1000 platinum resistor

Metrological Class

Class 2, (EN1434)

Maximum Operation Pressure

1.6Mpa

Pressure Loss

P<25kPa at qp

Pressure Stage

PN16

Protection Class

IP65 or IP68

Battery

6/ 10/ 16 years service life

Data Storage

36 months history data, including accumulated heat energy and volume,etc.

Total heat energy, volume, running hours,etc..

Operating Temperature

-30℃ – 55℃

Interface & Communication

M-Bus

Optical port

Pulse Output / Pulse Input

RS-485

LPWAN (LoRaWAN, Sigfox)

Installation

Horizontal or Vertical

Display and Indication

Unit: kWh, MWh, Gcal (optional)

LCD: 8-digit (back illumination)

Accumulated: 0.1kWh-9999999.9kWh.

Standard Compliance

EN13757