Description
IoT Ready
B12 VI-B supports multiple communication interfaces for both wired and wireless which suitable for any type of installation environment, e.g. M-Bus, RS485 (Modbus), Pulse, LoRaWAN (433MHz, 868MHz, 915MHz, 923MHz), Sigfox.
Flexible Battery Life Span
B12 VI-B has no moving parts, presents as IP65, and its body is fabricated from durable brass material. This robust design makes the B12 VI-B maintenance-free and highly precise throughout its flexible 6 or 10 or 15 years battery life depends upon customers’ needs.
Ultrasonic Flow Metering Unit
Ultrasonic flow meter measures by the transfer of ultrasound signals between transducers with the help of mirrors.
Temperature Metering Unit
PT1000 type heat sensors are used which they are calibrated, certified. If input water temperature metering prob is integrated with the meter body where flow meter is, thus the output water temperature metering prob is mounted to a suitable point on the network return water direction. Also meter could be installed in out flow position. Default cable length is 1.5m, but 3m length is also available as per request.
Calculator Unit
It is the unit that process energy calculation by the flow rate data received from flow rate metering unit and temperature data received from temperature metering unit. Its calibration is performed in software at factory.Calculated energy and other information is displayed on the LCD when button is pushed. These information may be remotely read via optical port and communication unit.
Specifications
|
Model |
B12 VI-B-15 |
B12 VI-B-20 |
B12 VI-B-25 |
B12 VI-B-32 |
B12 VI-B-40 |
|
Pipe Diameter |
DN15 |
DN20 |
DN25 |
DN32 |
DN40 |
|
Minimum Flow Rate, qi (m³/h) |
0.03 |
0.05 |
0.07 |
0.12 |
0.2 |
|
Permanent Flow Rate, qp (m³/h) |
1.5 |
2.5 |
3.5 |
6 |
10 |
|
Maximum Flow Rate, qs (m³/h) |
3.0 |
5.0 |
7.0 |
12 |
20 |
|
Connection |
G3/4′ |
G1′ |
G1 1/4′ |
G1 1/2′ |
G2′ |
|
Length (mm) |
110 |
130 |
160 |
180 |
200 |
|
Width (mm) |
96 |
105 |
114 |
120 |
130 |
|
Temperature |
Range: 4℃ – 95℃, T: 3k – 65k |
|
Temperature Sensor |
A pair of PT1000 platinum resistor |
|
Metrological Class |
Class 2, (EN1434) |
|
Maximum Operation Pressure |
1.6Mpa |
|
Pressure Loss |
P<25kPa at qp |
|
Pressure Stage |
PN16 |
|
Protection Class |
IP65 or IP68 |
|
Battery |
6/ 10/ 16 years service life |
|
Data Storage |
36 months history data, including accumulated heat energy and volume,etc. Total heat energy, volume, running hours,etc.. |
|
Operating Temperature |
-30℃ – 55℃ |
|
Interface & Communication |
M-Bus Optical port Pulse Output / Pulse Input RS-485 LPWAN (LoRaWAN, Sigfox) |
|
Installation |
Horizontal or Vertical |
|
Display and Indication |
Unit: kWh, MWh, Gcal (optional) LCD: 8-digit (back illumination) Accumulated: 0.1kWh-9999999.9kWh. |
|
Standard Compliance |
EN13757 |






Reviews